Serial number: 712935416
Name: Concrete conveying rubber hose
Spec: By use of matching
Memo: XJG–3
Class: Wear resistant hose series
 
Model DN50(2Inch) DN65(2.5Inch) DN80(3Inch) DN100(4Inch) DN125(5Inch) DN150( 6Inch)
Length 1 m -20 m steel wire rubber hose
Wire 1 layer 2 layers 4 layers 6 layers according to customer requirements
Pressure 85bar 130bar 200bar
Material Wear natural rubber, synthetic materials, steel wire
Purpose Fine aggregate sand pump concrete pump truck concrete pump concrete pile
Package The preparation of plastic packaging bags

Notes:
        1.Operators should be prepared prior to use standard training, standard operator may not have the posts, the connection to prevent the tube end when the card is not card tight seal damage and no additional ring, take over the flange when the model does not use the same pipe. Ordinary steel curtain-type hose and hose ends can only be exported for use, not a substitute for connecting pipe and straight pipe to use, unauthorized use of responsibility pay.
        2.Plugging must deal with normal use, such as the accumulation of concrete blocking the exit tube, mixed warehouse-type blocking pipe, pipe spilled slurry-type blocking pipe, concrete block intermittent time-out type tube, pipe ash accumulation skin type blockage, concrete mortar Segregation type blockage, concrete segregation type blockage, plugging additives segregation Type, S-type duct blockage, outside temperature very hot model blockage, and outdoor temperature extremely cold type blockage, plugging air compression type, diameter variation Plugging pipe, inhaled foreign body blockage, aggregate large blockage, traffic control type blockage, too large or too small slump plugging so. Paranormal will not rule out the increase in time to promote tube distortion, tube extrusion and paddling aggregate collision wall, resulting in accumulation of parts of hose expansion, especially in the concrete aggregate size of 3.5cm will appear very large of the blockade, forced output The longer the greater the damage, also causing hose which pierced the wall collision abnormal increasingly large, the final bulge appears at the skin from small to large phenomena, such as flange Department will constitute the same consequences occur (tube Bonding Agency head flange off). But as long as all aspects of the correct state is chosen will get the best position achieved by concrete, reducing unnecessary losses.
        3.The company has acquired the knowledge to use end of hose, new and old customers to our company based on the actual situation of the staff of all diplomatic advice, also like him to use the Company to provide new knowledge, design, transformation and so on.